Your Acrylic Panel Solution Provider & Factory
Grandview Acrylic supplies
custom cast acrylic panels
for swimming pool windows, infinity-pool edges, underwater viewing areas and large aquarium projects.
Panels can be cut, machined, shaped or bonded according to project dimensions and structural requirements.
We work with pool builders, contractors, designers and project owners, providing
material selection, engineering drawings, production, installation guidance and project-specific
technical support.
![]() | Product | Custom Cast Acrylic Panel |
| Thickness | 40–60 mm, 80–100 mm and 120–200 mm; custom thicknesses up to 1,000 mm, subject to engineering and production review | |
| Size | Stock panel sizes up to approximately 3 × 9 m; custom-cut and bonded sizes available | |
| Material | Cast PMMA acrylic manufactured from virgin MMA raw material | |
| Shapes | Flat, L-shaped, U-shaped, curved and cylindrical | |
| Warranty | Written warranty terms provided according to the product and project specification | |
| VST | 103°C Vicat Softening Temperature | |
| Test Documents | Material test reports and relevant CE, SVHC, California Proposition 65 and CPSIA documentation available according to the selected product | |
| Installation | Shop drawings, waterproofing guidance and on-site installation support |
Engineering note: Final panel dimensions and thickness should be confirmed
according to the viewing area, water depth, support configuration, loading and installation structure.


Material Quality
Material selection for an acrylic pool window should be based on measurable performance.
Grandview Acrylic provides test data covering important
optical, tensile, flexural, compressive, thermal and impact-related properties
of cast acrylic panels.
![]() | ![]() | ![]() | ![]() |
| Compressive Modulus | Deflection Temperature Under Load | Flexural Strength | Izod Notched Impact |
![]() | ![]() | ![]() | ![]() |
| Mean Coefficient of Linear Thermal Expansion | Rockwell Hardness | Shear Strength | Tensile Modulus and Strain |
| Property | Tested Value | Test Standard |
|---|---|---|
| Rockwell Hardness | 112L | ISO 2039-2:1999 |
| Tensile Modulus | 3150 MPa | EN ISO 527:2012 |
| Tensile Strength | 80.0 MPa | EN ISO 527:2012 |
| Tensile Strain at Break | 3.2% | EN ISO 527-1:2012 |
| Water Absorption | 0.20% | ISO 62:2008 Method 1 |
| Total Luminous Transmittance | 92.5% | ISO 13468-1:1996 |
| Vicat Softening Temperature | 103°C | ISO 306:2013 Method B50 |
| Light Ageing Test – UV Exposure | Grey scale: 5 | ISO 4892-3:2016 Cycle 1 |
| Mean Coefficient of Linear Thermal Expansion | 72 × 10−6 K−1 | ISO 11359-1:2014 |
| Compressive Stress at Yield | 129 MPa | EN ISO 604:2003 |
| Flexural Strength | 120 MPa | ISO 178:2013 |
| Izod Notched Impact Strength | 101 J/m | ASTM D256-10 Method A |
| Compressive Yield Strength | 111 MPa | ASTM D695-15 |
| Compressive Modulus | 3450 MPa | ASTM D695-15 |
| Shear Strength | 59.7 MPa | ASTM D732-17 |
| Deflection Temperature Under Load | 100.2°C | ASTM D648-18 Method B |
| Modulus of Elasticity | 2810 MPa | ASTM D695-15 |
Production Capacity
Grandview Acrylic maintains a range of thick cast acrylic panel sizes for pool and aquarium
projects. Standard flat panels may be available with a lead time of approximately
7–10 days, subject to current stock, machining, edge finishing and final specifications.
| L × W (mm) | T (mm) | L × W (mm) | T (mm) | L × W (mm) | T (mm) | L × W (mm) | T (mm) |
|---|---|---|---|---|---|---|---|
| 1300 × 2500 | 20–70 | 1650 × 3150 | 20–100 | 5000 × 1800 | 30–150 | 8200 × 3000 | 80–250 |
| 1350 × 2650 | 20–100 | 3200 × 2200 | 20–110 | 5500 × 2100 | 30–150 | 8700 × 3000 | 80–250 |
| 1450 × 2700 | 20–100 | 3500 × 1650 | 20–110 | 6200 × 3000 | 50–250 | 9150 × 3000 | 100–250 |
| 1600 × 2600 | 20–100 | 4250 × 2750 | 30–110 | 6700 × 3000 | 50–250 | 8100 × 3700 | 120–300 |
Availability notice: Stock dimensions and lead times should be reconfirmed before
quotation. Bonded, curved or specially machined panels normally require additional production time.

Engineering Support
Before production, 3D drawings can present the acrylic panel shape, dimensions, support structure
and expected appearance within the completed project. This helps the contractor and project team
review important details before manufacturing begins.
![]() | ![]() | ![]() |
| Panel and Support Design | Finite Element Analysis | Loading and Deflection Review |
Finite element analysis can be used to evaluate predicted loading and panel deflection under defined
project conditions. Final recommendations depend on the submitted dimensions, water depth, support
method and structural information.
![]() | ![]() | ![]() |
| Project Drawing | Installation Structure | Project Visualization |
Installation Support
For contractor-led installation, Grandview can provide guidance covering the
rabbet structure and dimensions, pre-installation checks, panel handling,
waterproofing, sealing and maintenance.
![]() | ![]() | ![]() |
| Rabbet and Support Detail | Waterproofing Detail | Structural Coordination |
Shop drawings help coordinate the acrylic panel with the concrete or steel support structure
before delivery and installation.
![]() | ![]() | ![]() |
| Installation Shop Drawing | Construction Dimensions | Sealing and Installation Detail |
On-site support: Installation service by the Grandview team may be arranged
according to the project location, site conditions, schedule and agreed service scope.
An acrylic pool window is not selected by visible dimensions alone. Panel thickness and
installation design also depend on the water depth, support configuration, expected loading
and allowable deflection.
| Three-Side Support | Four-Side Support | Custom Configurations |
|---|---|---|
| Common for pool end panels and wet-edge designs. The panel is supported along the bottom and both side edges, while the top remains open. | The panel is set into rebates on all four sides and may be used where additional structural restraint is required. | Curved, L-shaped, U-shaped, floor and bonded panels can be reviewed for pools, spas, underwater rooms and architectural water features. |
Yes. Panel length, height, thickness, shape and edge finish can be customized after reviewing
the project drawings, viewing area, support structure and water depth.
Thickness depends on the panel dimensions, maximum water depth, support configuration,
loading and allowable deflection. Final selection should follow a project-specific engineering review.
Yes. Grandview can provide shop drawings and guidance covering the rabbet, pre-installation
inspection, panel handling, waterproofing, sealing and maintenance.
On-site installation support may be arranged depending on the project location,
installation schedule, site conditions and agreed service scope.
To evaluate your project and prepare a quotation, please provide:
Outdoor anti-UV, the color change a little, non-yellowing or cloudy
Vicat Softening Temperature and Tensile strength Test each batch of Acrylic panels
All machined acrylic products is annealed to relieve stress
Superb bonding technology, so that the seams perfect
All new raw material MMA from Lucite factory local Shanghai
Strong Production Capacity, Huge stock, Fast delivery
Please give us a message for your enquiry, order or advice. Thanks a lot.